EMC 10 EPBIOS UNIT NUMBER FLASHING
Osman Bayrak
THE DISPLAY IS FLASHING EPBIOS UNIT NUMBER AND THE EMC 10 WILL NOT COME ON LINE:
- EDS II or III has to be booted at the computer for the machine to come on line.
- Must send a design for the machine to come on line.
- Enable a second machine to make sure EDS is scanning for peripherals.
- Refer to page 10-3 in the EDS2 manual and page 11-2 in the EDS3 manual, for instructions on how to use the Disable and Enable function.
- Reconfiguring the machine is a good practice for proper function with EDS and the RSA files. Refer to the Operation Manual in the table of contents and see: "Configuring the EMC10"
- Check the computer to peripheral Interface Cable, making sure that it is connected and not damaged at both ends.
- Interface Cables are available in various lengths call your distributor for part numbers. The total length shouldn't exceed 200 feet for all peripherals in the network.
- Perform the 5Volt Test according to the information in the technical manual: Power Supply (5Volt Setting)
- The CPU PCB may be defective in the machine. Call your distributor to order the CPU PCB. Refer to the Technical Manual for replacement instructions.
- The Computer Network Board may be improperly configured or damaged. Check EDS for proper configuration and set up.
- If still not coming on line, call your distributor for a service call.