Pearl PTM - ROUTINE MAINTENANCE & ADJUSTMENTS

customer

 With normal use of the Pearl PTM, a few routine maintenance procedures will be required to follow to ensure proper operation. If desired operation is not within the range of factory default settings, the motor and auto prime timing can also be adjusted.

1. Tightening the Belt.

The belt drive system may become loose over time. It is required to tighten the belt if the tension
becomes loose.

  1. Use a Hex Key to loosen the two bolts under the motor plate
  2. Push the motor plate outwards to the right of the rail system to tighten the belt.
  3. Tighten the two bolts under the motor plate.

 2. Lubricating the Rail.

If low spray densities are desired, proper lubrication of the rail system is required.

  1. Enter the Maintenance Menu by pressing the Maintenance Menu icon.
  2. Spray the rail with a silicone based lubricant.
  3. Press the rail on the screen to move the Nozzle Cart to spread the lubricant over the rail.

 3. Adjusting Motor Speed

The motor speed can be adjusted to produce a smaller or larger spray density.

  1. Enter the Maintenance Menu by pressing the Maintenance Menu icon.
  2. Press the Adjust Button to open the Adjustments Settings Menu.
  3. Test the setting by pressing the rail to move the Nozzle Cart to that position.

 4. Adjusting Auto Prime Timing

The Auto Prime Timing is predetermined by a specific amount of time. If a longer or short timing is
desired, the Auto Prime Timing can be adjusted.

  1. Enter the Maintenance Menu by pressing the Maintenance Menu icon.
  2. Press the Adjust Button to open the Adjustments Settings Menu.
  3. Move the AUTO slider or press the increment/decrement to the desired setting.

 

 

Buy the Pearl PTM Pretreatment Machine here

Read a review on the Pearl PTM Pretreatment Machine here

Leave a comment